CONTROL CABLE XLPE NHLSFR ARM

Multicore Cable Description : Copper Conductor,XLPE Insulated,NHLSFR(Polyolefin) Inner Sheathed,Galvanised Steel Wire Armoured, Overall NHLSFR(Polyolefin) Outer Sheathed Low Voltage Control Cable.


  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per SANS:1507-5, ZS-688-5
  • Voltage Grade
    600/1000 Volt
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    2C X 1.5 Sq.mm up to 91C X 4.0 Sq.mm


CONTROL CABLE XLPE NHLSFR UA

Multicore Cable Description : Copper Conductor,XLPE Insulated,NHLSFR(Polyolefin) Inner Sheathed, Overall NHLSFR(Polyolefin) Outer Sheathed Low Voltage Unarmoured Control Cable.


  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per SANS:1507-5, ZS-688-5
  • Voltage Grade
    600/1000 Volt
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    2C X 1.5 Sq.mm up to 91C X 4.0 Sq.mm


FIVE CORE XLPE NHLSFR ARM

Five Core Cable Description : Copper Conductor,XLPE Insulated,NHLSFR(Polyolefin) Inner Sheathed,Galvanised Steel Wire Armoured, Overall NHLSFR(Polyolefin) Outer Sheathed Low Voltage Cable.


  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per SANS:1507-5, ZS-688-5
  • Voltage Grade
    600/1000 Volt
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    1.5 Sq.mm up to 500 Sq.mm


FIVE CORE XLPE NHLSFR UA

Five Core Cable Description : Copper Conductor,XLPE Insulated,NHLSFR(Polyolefin) Inner Sheathed, Overall NHLSFR(Polyolefin) Outer Sheathed Low Voltage Unarmoured Cable.


  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per SANS:1507-5, ZS-688-5
  • Voltage Grade
    600/1000 Volt
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    1.5 Sq.mm up to 500 Sq.mm


FOUR CORE XLPE NHLSFR UA

Four Core Cable Description : Copper Conductor,XLPE Insulated,NHLSFR(Polyolefin) Inner Sheathed, Overall NHLSFR(Polyolefin) Outer Sheathed Low Voltage Unarmoured Cable.


  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per SANS:1507-5, ZS-688-5
  • Voltage Grade
    600/1000 Volt
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    1.5 Sq.mm up to 500 Sq.mm


FOURE CORE XLPE NHLSFR ARM

Four Core Cable Description : Copper Conductor,XLPE Insulated,NHLSFR(Polyolefin) Inner Sheathed,Galvanised Steel Wire Armoured, Overall NHLSFR(Polyolefin) Outer Sheathed Low Voltage Cable.


  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per SANS:1507-5, ZS-688-5
  • Voltage Grade
    600/1000 Volt
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    1.5 Sq.mm up to 500 Sq.mm


THREE CORE XLPE NHLSFR ARM

Three Core Cable Description : Copper Conductor,XLPE Insulated,NHLSFR(Polyolefin) Inner Sheathed,Galvanised Steel Wire Armoured, Overall NHLSFR(Polyolefin) Outer Sheathed Low Voltage Cable.


  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per SANS:1507-5, ZS-688-5
  • Voltage Grade
    600/1000 Volt
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    1.5 Sq.mm up to 500 Sq.mm


THREE CORE XLPE NHLSFR UA

Three Core Cable Description : Copper Conductor,XLPE Insulated,NHLSFR(Polyolefin) Inner Sheathed, Overall NHLSFR(Polyolefin) Outer Sheathed Low Voltage Unarmoured Cable.


  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per SANS:1507-5, ZS-688-5
  • Voltage Grade
    600/1000 Volt
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    1.5 Sq.mm up to 500 Sq.mm


THREE & HALF XLPE NHLSFR ARM

Three Core with Reduced Neutral Cable Description : Copper Conductor,XLPE Insulated,NHLSFR(Polyolefin) Inner Sheathed,Galvanised Steel Wire Armoured, Overall NHLSFR(Polyolefin) Outer Sheathed Low Voltage Cable.


  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per SANS:1507-5, ZS-688-5
  • Voltage Grade
    600/1000 Volt
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    25 Sq.mm up to 500 Sq.mm


THREE & HALF XLPE NHLSFR UA

Three Core with Reduced Neutral Cable Description : Copper Conductor,XLPE Insulated,NHLSFR(Polyolefin) Inner Sheathed, Overall NHLSFR(Polyolefin) Outer Sheathed Low Voltage Unarmoured Cable.


  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per SANS:1507-5, ZS-688-5
  • Voltage Grade
    600/1000 Volt
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    25 Sq.mm up to 500 Sq.mm


TWO CORE XLPE NHLSFR UA

Two Core Cable Description : Copper Conductor,XLPE Insulated,NHLSFR(Polyolefin) Inner Sheathed, Overall NHLSFR(Polyolefin) Outer Sheathed Low Voltage Unarmoured Cable.


  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per SANS:1507-5, ZS-688-5
  • Voltage Grade
    600/1000 Volt
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    1.5 Sq.mm up to 500 Sq.mm


TWO COR XLPE NHLSFR ARM

Two Core Cable Description : Copper Conductor,XLPE Insulated,NHLSFR(Polyolefin) Inner Sheathed,Galvanised Steel Wire Armoured, Overall NHLSFR(Polyolefin) Outer Sheathed Low Voltage Cable.


  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per SANS:1507-5, ZS-688-5
  • Voltage Grade
    600/1000 Volt
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    1.5 Sq.mm up to 500 Sq.mm


SINGLE CORE XLPE NHLSFR ARM

Single Core Cable Description : Copper Conductor,XLPE Insulated,NHLSFR(Polyolefin) Inner Sheathed,Aluminium Wire Armoured, Overall NHLSFR(Polyolefin) Outer Sheathed Low Voltage Cable.


  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per SANS:1507-5, ZS-688-5
  • Voltage Grade
    600/1000 Volt
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    Single Core 16 Sq.mm up to 1000 Sq.mm


SINGLE CORE XLPE NHLSFR UA

Single Core Cable Description : Copper Conductor,XLPE Insulated, Overall NHLSFR(Polyolefin) Outer Sheathed Low Voltage Unarmoured Cable.


  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per SANS:1507-5, ZS-688-5
  • Voltage Grade
    600/1000 Volt
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    Single Core 16 Sq.mm up to 1000 Sq.mm