CONTROL CABLE XLPE LHFR ARM

MultiCore Cable Description : Copper Conductor,XLPE Insulated,PVC-LHFR Inner Sheathed,Galvanised Steel Wire Armoured, Overall LHFR- PVC Outer Sheathed Low Voltage Control Cable.


  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per SANS:1507-4, ZS-688-4, & BS 5467
  • Voltage Grade
    600/1000 Volt
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    2C X 1.5 Sq.mm up to 91C X 4.0 Sq.mm


CONTROL CABLE XLPE LHFR UA

MultiCore Cable Description : Copper Conductor,XLPE Insulated,PVC-LHFR Inner Sheathed, Overall LHFR- PVC Outer Sheathed Low Voltage Unarmoured Control Cable.


  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per SANS:1507-4, ZS-688-4, & BS 5467
  • Voltage Grade
    600/1000 Volt
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    2C X 1.5 Sq.mm up to 91C X 4.0 Sq.mm


SINGLE CORE XLPE LHFR ARM

Single Core Cable Description : Copper Conductor,XLPE Insulated,PVC-LHFR Inner Sheathed,Aluminium Wire Armoured, Overall LHFR- PVC Outer Sheathed Low Voltage Cable.


  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per SANS:1507-4, ZS-688-4, & BS 5467
  • Voltage Grade
    600/1000 Volt
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    Single Core 16 Sq.mm up to 1000 Sq.mm


SINGLE CORE XLPE LHFR UA

Single Core Cable Description : Copper Conductor, XLPE Insulated, Overall LHFR- PVC Outer Sheathed Low Voltage Unarmoured Cable.


  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per SANS:1507-4, ZS-688-4, & BS 5467
  • Voltage Grade
    600/1000 Volt
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    Single Core 16 Sq.mm up to 1000 Sq.mm


TWO CORE XLPE LHFR ARM

Two Core Cable Description : Copper Conductor,XLPE Insulated,PVC-LHFR Inner Sheathed,Galvanised Steel Wire Armoured, Overall LHFR- PVC Outer Sheathed Low Voltage Cable.


  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per SANS:1507-4, ZS-688-4, & BS 5467
  • Voltage Grade
    600/1000 Volt
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    1.5 Sq.mm up to 500 Sq.mm


TWO CORE XLPE LHFR UA

Two Core Cable Description : Copper Conductor, XLPE Insulated,PVC-LHFR Inner Sheathed, Overall LHFR- PVC Outer Sheathed Low Voltage Unarmoured Cable.


  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per SANS:1507-4, ZS-688-4, & BS 5467
  • Voltage Grade
    600/1000 Volt
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    1.5 Sq.mm up to 500 Sq.mm


THREE CORE XLPE LHFR ARM

Three Core Cable Description : Copper Conductor,XLPE Insulated,PVC-LHFR Inner Sheathed,Galvanised Steel Wire Armoured, Overall LHFR- PVC Outer Sheathed Low Voltage Cable.


  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per SANS:1507-4, ZS-688-4, & BS 5467
  • Voltage Grade
    600/1000 Volt
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    1.5 Sq.mm up to 500 Sq.mm


THREE CORE XLPE LHFR UA

Three Core Cable Description : Copper Conductor,XLPE Insulated,PVC-LHFR Inner Sheathed, Overall LHFR- PVC Outer Sheathed Low Voltage Unarmoured Cable.


  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per SANS:1507-4, ZS-688-4, & BS 5467
  • Voltage Grade
    600/1000 Volt
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    1.5 Sq.mm up to 500 Sq.mm


THREE & HALF XLPE LHFR ARM

Three Core with Reduced Neutral Cable Description : Copper Conductor, XLPE Insulated,PVC-LHFR Inner Sheathed, Galvanised Steel Wire Armoured, Overall LHFR- PVC Outer Sheathed Low Voltage Cable.


  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per SANS:1507-4, ZS-688-4, & BS 5467
  • Voltage Grade
    600/1000 Volt
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    25 Sq.mm up to 500 Sq.mm


THREE & HALF XLPE LHFR UA

Three Core with Reduced Neutral Cable Description : Copper Conductor, XLPE Insulated,PVC-LHFR Inner Sheathed, Overall LHFR- PVC Outer Sheathed Low Voltage Unarmoured Cable.


  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per SANS:1507-4, ZS-688-4, & BS 5467
  • Voltage Grade
    600/1000 Volt
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    25 Sq.mm up to 500 Sq.mm


FOUR CORE XLPE LHFR ARM

Four Core Cable Description :Copper Conductor,XLPE Insulated,PVC-LHFR Inner Sheathed,Galvanised Steel Wire Armoured, Overall LHFR- PVC Outer Sheathed Low Voltage Cable.


  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per SANS:1507-4, ZS-688-4, & BS 5467
  • Voltage Grade
    600/1000 Volt
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    1.5 Sq.mm up to 500 Sq.mm


FOUR CORE XLPE LHFR UA

Four Core Cable Description : Copper Conductor, XLPE Insulated,PVC-LHFR Inner Sheathed, Overall LHFR- PVC Outer Sheathed Low Voltage Unarmoured Cable.


  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per SANS:1507-4, ZS-688-4, & BS 5467
  • Voltage Grade
    600/1000 Volt
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    1.5 Sq.mm up to 500 Sq.mm


FIVE CORE XLPE LHFR ARM

Five Core Cable Description : Copper Conductor,XLPE Insulated,PVC-LHFR Inner Sheathed,Galvanised Steel Wire Armoured, Overall LHFR- PVC Outer Sheathed Low Voltage Cable.


  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per SANS:1507-4, ZS-688-4, & BS 5467
  • Voltage Grade
    600/1000 Volt
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    1.5 Sq.mm up to 500 Sq.mm


FIVE CORE XLPE LHFR UA

Five Core Cable Description : Copper Conductor,XLPE Insulated,PVC-LHFR Inner Sheathed, Overall LHFR- PVC Outer Sheathed Low Voltage Unarmoured Cable.


  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per SANS:1507-4, ZS-688-4, & BS 5467
  • Voltage Grade
    600/1000 Volt
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    1.5 Sq.mm up to 500 Sq.mm