THREE CORE FR 30KV ARM

Three Core Cable Description : Copper Conductor,Semi-conducting conductor Screen,XLPE Insulated,Semi-conducting Insulation screen, Metallic screen over Individual
Core,FR- PVC Inner Sheathed, Galvanised Steel Wire Armoured, Overall FR-PVC Outer Sheathed,Medium Voltage Cable.

  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per IEC 60502-2
  • Voltage Rating ( Uo / U)
    18/30 kV
  • Maximum Operating Voltage ( Um)
    36 Kv
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    Three Core 50 Sq.mm up to 300 Sq.mm

THREE CORE FR 30KV UA

Three Core Cable Description : Copper Conductor,Semi-conducting conductor Screen,XLPE Insulated,Semi-conducting Insulation screen, Metallic screen over Individual
Core,FR- PVC Inner Sheathed, Overall FR-PVC Outer Sheathed,Medium Voltage Unarmoured Cable.

  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per IEC 60502-2
  • Voltage Rating ( Uo / U)
    18/30 kV
  • Maximum Operating Voltage ( Um)
    36 Kv
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    Three Core 50 Sq.mm up to 300 Sq.mm

THREE CORE LHFR 30KV ARM

Three Core Cable Description : Copper Conductor,Semi-conducting conductor Screen,XLPE Insulated,Semi-conducting Insulation screen, Metallic screen over Individual
Core, PVC-FR Inner Sheathed, Galvanised Steel Wire Armoured, Overall UV Stabilized Polyethylene (PE) Outer Sheathed,Medium Voltage Cable.

  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per IEC 60502-2
  • Voltage Rating ( Uo / U)
    18/30 kV
  • Maximum Operating Voltage ( Um)
    36 Kv
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    Three Core 50 Sq.mm up to 300 Sq.mm

THREE CORE LHFR 30KV UA

Three Core Cable Description : Copper Conductor,Semi-conducting conductor Screen,XLPE Insulated,Semi-conducting Insulation screen, Metallic screen over Individual
Core,LHFR- PVC Inner Sheathed, Overall LHFR-PVC Outer Sheathed,Medium Voltage Unarmoured Cable.

  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per IEC 60502-2
  • Voltage Rating ( Uo / U)
    18/30 kV
  • Maximum Operating Voltage ( Um)
    36 Kv
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    Three Core 50 Sq.mm up to 300 Sq.mm

THREE CORE NHLSFR 30KV ARM

Three Core Cable Description : Copper Conductor,Semi-conducting conductor Screen,XLPE Insulated,Semi-conducting Insulation screen, Metallic screen over Individual
Core, NHLSFR (Polyolefin) Inner Sheathed, Galvanised Steel Wire Armoured, Overall NHLSFR(Polyolefin) Outer Sheathed,Medium Voltage Cable.

  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per IEC 60502-2
  • Voltage Rating ( Uo / U)
    18/30 kV
  • Maximum Operating Voltage ( Um)
    36 Kv
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    Three Core 50 Sq.mm up to 300 Sq.mm

THREE CORE NHLSFR 30KV UA

Single Core Cable Description : Copper Conductor,Semi-conducting conductor Screen,XLPE Insulated,Semi-conducting Insulation screen, Metallic screen over Individual Core, Overall UV Stabilized Polyethylene (PE) Outer Sheathed,Medium Voltage Unarmoured Cable.


  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per IEC 60502-2
  • Voltage Rating ( Uo / U)
    8.7/15 kV
  • Maximum Operating Voltage ( Um)
    17.5 kV
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    Three Core 25 Sq.mm up to 300 Sq.mm

THREE CORE PE 30KV ARM


THREE CORE PE 30KV UA

Three Core Cable Description : Copper Conductor,Semi-conducting conductor Screen,XLPE Insulated,Semi-conducting Insulation screen, Metallic screen over Individual
Core, PVC-FR Inner Sheathed, Overall UV Stabilized Polyethylene (PE) Outer Sheathed,Medium Voltage Unarmoured Cable.

  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per IEC 60502-2
  • Voltage Rating ( Uo / U)
    18/30 kV
  • Maximum Operating Voltage ( Um)
    36 Kv
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    Three Core 50 Sq.mm up to 300 Sq.mm