SINGLE CORE 6.6KV NHLSFR ARM

Single Core Cable Description : Copper Conductor,Semi-conducting conductor Screen,XLPE Insulated,Semi-conducting Insulation screen, Metallic screen over Individual Core, NHLSFR (Polyolefin) Inner Sheathed, Aluminium Wire Armoured, Overall NHLSFR(Polyolefin) Outer Sheathed,Medium Voltage Cable.



  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per SANS:1339:2017
  • Voltage Rating ( Uo / U)
    3.8/6.6 kV
  • Maximum Operating Voltage ( Um)
    7.2 kV
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    Single Core 50 Sq.mm up to 1000 Sq.mm

SINGLE CORE 6.6KV NHLSFR UA

Single Core Cable Description : Copper Conductor,Semi-conducting conductor Screen,XLPE Insulated,Semi-conducting Insulation screen, Metallic screen over Individual Core, NHLSFR (Polyolefin) Inner Sheathed, Aluminium Wire Armoured, Overall NHLSFR(Polyolefin) Outer Sheathed,Medium Voltage Cable.



  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per SANS:1339:2017
  • Voltage Rating ( Uo / U)
    3.8/6.6 kV
  • Maximum Operating Voltage ( Um)
    7.2 kV
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    Single Core 50 Sq.mm up to 1000 Sq.mm

SINGLE CORE 6.6KV PE UA

Single Core Cable Description : Copper Conductor,Semi-conducting conductor Screen,XLPE Insulated,Semi-conducting Insulation screen, Metallic screen over Individual Core, Overall UV Stabilized Polyethylene (PE) Outer Sheathed,Medium Voltage Unarmoured Cable.


  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per SANS:1339:2017
  • Voltage Rating ( Uo / U)
    3.8/6.6 kV
  • Maximum Operating Voltage ( Um)
    7.2 kV
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    Single Core 50 Sq.mm up to 1000 Sq.mm

SINGLE CORE 6.6KV FR ARM

Single Core Cable Description : Copper Conductor,Semi-conducting conductor Screen,XLPE Insulated,Semi-conducting Insulation screen, Metallic screen over Individual Core,FR- PVC Inner Sheathed, Aluminium Wire Armoured, Overall FR-PVC Outer Sheathed,Medium Voltage Cable.


  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per SANS:1339:2017
  • Voltage Rating ( Uo / U)
    3.8/6.6 kV
  • Maximum Operating Voltage ( Um)
    7.2 kV
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    Single Core 50 Sq.mm up to 1000 Sq.mm

SINGLE CORE 6.6KV FR UA

Single Core Cable Description : Copper Conductor,Semi-conducting conductor Screen,XLPE Insulated,Semi-conducting Insulation screen, Metallic screen over Individual Core, Overall FR-PVC Outer Sheathed,Medium Voltage Cable.




  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per SANS:1339:2017
  • Voltage Rating ( Uo / U)
    3.8/6.6 kV
  • Maximum Operating Voltage ( Um)
    7.2 kV
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    Single Core 50 Sq.mm up to 1000 Sq.mm

SINGLE CORE 6.6KV PE ARM

Single Core Cable Description : Copper Conductor,Semi-conducting conductor Screen,XLPE Insulated,Semi-conducting Insulation screen, Metallic screen over Individual Core, PVC-FR Inner Sheathed, Aluminium Wire Armoured, Overall UV Stabilized Polyethylene (PE) Outer Sheathed,Medium Voltage Cable.


  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per SANS:1339:2017
  • Voltage Rating ( Uo / U)
    3.8/6.6 kV
  • Maximum Operating Voltage ( Um)
    7.2 kV
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    Single Core 50 Sq.mm up to 1000 Sq.mm

SINGLE CORE LHFR 6.6KV ARM

Single Core Cable Description : Copper Conductor,Semi-conducting conductor Screen,XLPE Insulated,Semi-conducting Insulation screen, Metallic screen over Individual Core,LHFR- PVC Inner Sheathed, Aluminium Wire Armoured, Overall LHFR-PVC Outer Sheathed,Medium Voltage Cable.


  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per SANS:1339:2017
  • Voltage Rating ( Uo / U)
    3.8/6.6 kV
  • Maximum Operating Voltage ( Um)
    7.2 kV
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    Single Core 50 Sq.mm up to 1000 Sq.mm

SINGLE CORE LHFR 6.6KV UA

Single Core Cable Description : Copper Conductor,Semi-conducting conductor Screen,XLPE Insulated,Semi-conducting Insulation screen, Metallic screen over Individual Core, Overall LHFR-PVC Outer Sheathed,Medium Voltage Cable.



  • Make
    NEELKANTH CABLES LIMITED
  • Reference Standard
    As per SANS:1339:2017
  • Voltage Rating ( Uo / U)
    3.8/6.6 kV
  • Maximum Operating Voltage ( Um)
    7.2 kV
  • Operating Temperature
    90°C
  • Max. Temp. During Short Circuit
    250°C
  • Range of Product
    Single Core 50 Sq.mm up to 1000 Sq.mm